Showing results: 121 - 135 of 338 items found.
-
CBT4 -
Shanghai Powoo Industry Develop Group Limited
- Completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - more space in meter can be saved with combined current transformer in comparison to that of the same number of single form current transformers; - HLX-2 is used for 3-phase-3-wire circuits; HLX-3 is used for 3-phase-4-wire circuits;
-
DVDF -
AJIT Electronics Co.
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
SG3004-12(14) -
Shanghai Jiuzhi Electric Co., Ltd.
High voltage impulse test is used to assess the quality of any high voltage equipment. The test object is subjected to a fast voltage impulse of defined wave shape caused by the test object are used for detection of insulation strengths and/or faults. It is commonly used for routine testing of transformer, bushings or other high voltage equipment.
-
Hilkar
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
Weshine Electric Manufacturing Co., Ltd
Transformer iron core grounding current tester is a high-precision clamp meter specially designed for measuring AC leakage current, current and voltage. Large diameter (80×80mm) can clamp φ80mm cable, or 96mm×4mm flat steel ground wire, suitable for cables Leakage detection and transformer grounding flat steel leakage measurement.
-
MR 8050 -
Schuetz Messtechnik GmbH
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
ATG 2 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
ATG 6000 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
Supreme Instrument Laboratories
Single Phase A.C. High Voltage Test set (BDV Flash Test) suitable for operation on 230 Volts, A.C. 50 Hz., designed for carrying out dielectric test on transformers, electrical switchgears, and installations. It operates on single phase A.C. and provides an output voltage zero to maximum rated voltage.
-
WB2671A/WB2671B -
Lisun Electronics Inc.
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
RG-5 -
Control Sciences Inc.
Programmable Frequency & Voltage Portable Sine Wave Generator Sunlight Readlable Display Transformer Isolated Output 360 - 11000 Hz with 1Hz Resolution 1.9V to 125V Output with AGC
-
Osborne Transformer Corp.
Osborne Potential Transformers (PT’s) are used to reduce higher system voltages to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when potential transformers are to be used for power measuring applications.
-
Neutronics Manufacturing Co.
NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.
-
SGMF(T) Series -
Shanghai Jiuzhi Electric Co., Ltd.
Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument transformers, GIS, GIL, switchgears and etc after they are installed onsite and for purposes of diagnostics in asset management up to 900kV/10A.
-
PeakTech Prüf- und Messtechnik GmbH
This AC / AC voltage converter is particularly suitable for use with halogen indoor lights and other low-voltage light sources that require an AC voltage source for supply. There is a safe galvanic separation between mains and low voltage according to the isolating transformer standard. This pre-assembled AC / AC converter is equipped with an overtemperature switch that cannot be reset.